Home   

Lalitpur Super Thermal Power Plant (3x660 MW)


COD COMPLETION/progress

COD COMPLETION/progress

Plant view/progress

Plant view/progress

Plant view/progress

Plant view/progress

Plant view/progress

Plant view/progress

Unit #3‐LP Turbine Erection/Under progress

Unit #3‐ID Fan‐B Erection/ Under Progress

Unit #3‐ID Fan‐A Erection /Under progress

Unit #3‐HP Turbine Insulation /Completed

Unit #3‐Generator Erection/In progress

Unit #3‐Front released for Bottom Ash Hopper/In progress

Unit #3‐Coal Pipe Erection/In progress

Unit #2‐TDBFP‐B erection/In progress

Unit #2‐TDBFP‐A erection/In progress

Unit #2 Generator Erection/In progress

Unit #2 Coal piping erection/In progress

Inauguration Function/20th September, 2015

Inauguration Function/20th September, 2015

Inauguration Function/20th September, 2015

Inauguration Function/20th September, 2015

Inauguration Function/20th September, 2015

Inauguration Function/20th September, 2015

Inauguration Function/20th September, 2015

Inauguration Function/20th September, 2015

Inauguration Function/20th September, 2015

Inauguration Function/20th September, 2015

Inauguration Function /20th September, 2015

Inauguration Function /20th September, 2015

Inauguration Function /20th September, 2015

Inauguration Function /20th September, 2015

Inauguration Function /20th September, 2015

Inauguration Function /20th September, 2015

Inauguration Function /20th September, 2015

Unit#3 DMCW Pump Frame Erection/In progress

Unit #3‐ Stator Unloading/In progress

Unit #3 MDBFP Motor Erection/In progress

Unit #3‐ Condenser Dome Wall Erection/In progress

Unit # 3 HP Heater Alignment/In progress

Unit #2‐LPBP Line Balance 3 joints – Welding/In progress

Unit #2‐Erection of IP valve spring support/In progress

Unit #2‐Erection of HP valve spring support ( Left

Unit #2‐CRH to Deaerator Pegging line Work/In progress

/



























Unit # 3/progress

Unit # 3/progress

Unit # 3/progress

Unit # 3/progress

Unit # 3/progress

Unit # 3/progress

unit#2/progress

unit#2/progress

unit#2/progress

unit#2/progress

unit#2/progress

Unit#1/progress

Unit#1/progress

Unit#1/progress

Unit#1/progress

Unit#1/progress

TG # 2/progress

TG# 1/progress

TG# 1/progress

TG# 1/progress

ESP #2

ESP #2

ESP #2

boiler # 3/progress

boiler # 3/progress

Boiler # 2/progress

Boiler # 2/progress

Boiler #1/progress

ESP 2-Insulation Under Progress/

ESP 2-Insulation Under Progress/

Unit 2- APH Erection Completed/

Unit 1- Turbine Insulation Completed/

Unit 1- CEP Erection Completed/

Unit 1- ESP Pass ‘D’ Insulation Under Progress/

ESP 3-Insulation Under Progress/

ESP 2-Insulation Under Progress/

Boiler 2-APH Erection Under Progress/

Unit‐1: TG Piping insulation/In Progress

Unit‐1: EDTA Cleaning Set Up/

UNIT 1- ASH HANDLING SYSTEM ERECTION IN PROGRESS (LPGCL SCOPE)/ In progress

UNIT 1- ID FAN TO CHIMNEY DUCT/In Progress

ACW CONTINGENCY ARRANGMENT BY LPGCL/

UNIT 1- COAL PIPING IN PROGRESS/ In progress

UNIT 1- SA DUCT INSULATION IN PROGRESS/ In progress

UNIT 1-RHS BUNKER SHELLS/In Progress

UNIT 1-RHS FEEDER FLOOR CIVIL WORKS COMPLETED (LPGCL SCOPE)/In Progress

CHP GALLERRIES ERECTION IN PROGRESS (LPGCL SCOPE)/In Progress

UNIT 1-CHP GALLERY FOR FEEDING BUNKERS (LPGCL SCOPE)/In Progress

CW SYSTEM (LPGCL SCOPE)/In Progress

UNIT1-BOILER INSULATION /In Progress

RAW WATER RESERVOIR, DM PLANT, WTP, CW PUMP HOUSE (LPGCL SCOPE)/ In progress

GT AREA

UNIT 1- PA

LDO

Light Up of Boiler Unit#1/

Wagon trippler (LPGCL scope)/In Progress

Erection of stacker reclaimers (LPGCL scope)/In Progress

Overview of AHP pump house (LPGCL scope)/In Progress

Overview of AHP pump house (LPGCL scope)/In Progress

Overview of CHP galleries and JNT erection (LPGCL scope)/In Progress

Overview of CHP galleries and JNT erection (LPGCL scope)/In Progress

Generator transformers/In Progress

Cooling towers/In Progress

CW Pump house and forebay/In Progress

DM Plant/In Progress

Main plant control room/In Progress

UNIT‐2: APH column foundation work/In Progress

UNIT‐3: TG Building /In Progress

UNIT‐3: Boiler Pass 1/In Progress

UNIT‐2: TG erection/In Progress

UNIT‐2: Condenser erection/In Progress

UNIT‐2: Boiler Erection/In Progress

UNIT‐1: MCC panel erection/In Progress

UNIT‐1: DCS panel erection/

UNIT‐1: TG erection/In Progress

UNIT‐1: RHS Mills/In Progress

UNIT‐1: LHS Mills/In Progress

UNIT‐1: RHS bunker Erection/In Progress

UNIT‐1: LHS bunker Erection/In Progress

UNIT‐1: Pipe Rack erection/In Progress

UNIT‐1: Pipe Rack erection /In Progress

UNIT‐1: ID fan B/In Progress

UNIT‐1: ID fan A /In Progress

UNIT‐1: FD fan A/In Progress

UNIT‐1: FD fan B/In Progress

UNIT‐1: Coal piping /In Progress

UNIT‐1:ESP erection/In Progress

UNIT‐1:Boiler Pass 2 insulation/In Progress

Unit‐1: Boiler Pass 1 insulation/In Progress

UNIT # 1 STG/LP box up

U # 2 BOILER/PROGRESS

U #1 FAN ERECTION/PROGRESS

BUNKER #1/PROGRESS

PLANT VIEW/PROGRESS

TG HALL/PROGRESS

TG HALL/PROGRESS

TG HALL/PROGRESS

TG HALL/PROGRESS

ESP #1/PROGRESS

U # 1 BOILER/PROGRESS

BOILER1/COAL PIPE COUPLING NOT AVAILABLE

BOILER1/WALL BLOWER SLEEVES NOT AVAILABLE PGMA-20204 DU-001

BOILER 1/SAFETY VALVE FOR MS LINE

TG 1/BFP foundation bolts are pending, Alignment held-up

TG 1/TDBFP Drive turbine foundation bolts

TG 1/ PIPING/TWIN COOLER FOR TDBFP-A PENDING

BOILER 3/ESP to ID fan Duct erection /WORK HELD UP DUE TO MATERIAL

BOILER 3/65 Nos Hanger and Screen assembly erected only One DU:07-223-006- 1qty required MDR:058, dated-21-11-13)

BOILER 3/Machine room approach platform Stairs

BOILER3/Headers are on lashing from 5 months , VLH Turnbuckle/Split pin/Locknut (against MDR) and Tie rod Turnbuckle for Imported VLH required (PG-MA:12-954-001 TO 013, 902, 903)

BOILER3/Tie rod of CLH req. (MDR-171)

BOILER3/WORK HELD UP DUE TO MATERIAL

ESP and ESP outlet to Chimney ducting Progress Image/PROGRESS

unit 3/Eco Coils preassembly under progress: PGMADU:19-814- 005: 1 qty is not available

unit 3/LTRH Coils preassembly under progress: PGMADU:16-235-001-1 qty is not available(MDR- 125, dated:11-03-14)

unit 3/Lift Structure along with purlins complete- 1. For Pit room and Machine room Civil drawing req. 2. Machine room approach platform Stairs: 38-820-All Du’s not available. 3. Metapoly sheets(PGMA:38-611-All Dus) not available.

unit 3/39-141: ESP Outlet Duct Support Structure; for approach platforms stairs are not available(39-820-AllDu’s)

Unit 3/39-101: ESP Inlet Duct Support Structure; for approach platforms stairs are not available(39-820-AllDu’s)

unit 1 boiler/Flash tank erection

unit 1 boiler/ID Fan to chimney ducting up-to terminal point(BHEL scope) completed

unit 1 boiler/P92 welding started for HRH piping- 1st time in Lalitpur

Unit 1 Boiler/Vertical roof enclosure work under progress

Unit 1 Boiler/CRH LINE-ERECTION WORK IN “CD” BAY

Mineral wool for pressure parts insulation not available at site/constraints

Hanger angle (256 nos.) holes wrongly drilled- Rework/Hanger angle (256 nos.) holes wrongly drilled- Rework

Castable

Flash tank exhaust pipe/work under hold for material(PGMA 80455)

UNIT 3/BOILER

UNIT 3/BOILER

UNIT 3/BOILER

UNIT 2/BOILER

UNIT 2/BOILER

UNIT 2/BOILER

UNIT 1/BOILER

UNIT 1/BOILER

UNIT 1/BOILER

UNIT 1/BOILER

MISC/PROGRESS

MISC/PROGRESS

MISC/PROGRESS

MISC/PROGRESS

MISC/PROGRESS

MISC/PROGRESS

UNIT 3 TG DECK/ERECTION WORKS

UNIT 1/CONDENSER

UNIT 1/CONDENSER

UNIT 3/BOILER

UNIT 3/BOILER

UNIT 2/SECOND PASS PP

UNIT 2/FIRST PASS PRESSURE PARTS

AHP

AHP

Unit 1 Boiler /Pressure parts erection

Unit 1 Boiler /Pressure parts erection